CVE-2026-44414
Описание уязвимости
Что произошло
A vulnerability has been identified in Industrial Edge Cloud Device (IECD), Industrial Edge Device Kit - arm64 V1.10, Industrial Edge Device Kit - arm64 V1.11, Industrial Edge Device Kit - arm64 V1.12, Industrial Edge Device Kit - arm64 V1.13, Industrial Edge Device Kit - arm64 V1.14, Industrial Edge Device Kit - arm64 V1.15, Industrial Edge Device Kit - arm64 V1.16, Industrial Edge Device Kit - arm64 V1.17, Industrial Edge Device Kit - arm64 V1.18, Industrial Edge Device Kit - arm64 V1.19, Industrial Edge Device Kit - arm64 V1.20, Industrial Edge Device Kit - arm64 V1.21, Industrial Edge Device Kit - arm64 V1.22, Industrial Edge Device Kit - arm64 V1.23, Industrial Edge Device Kit - arm64 V1.24, Industrial Edge Device Kit - arm64 V1.25, Industrial Edge Device Kit - arm64 V1.26, Industrial Edge Device Kit - arm64 V1.27, Industrial Edge Device Kit - arm64 V1.28, Industrial Edge Device Kit - arm64 V1.5, Industrial Edge Device Kit - arm64 V1.6, Industrial Edge Device Kit - arm64 V1.7, Industrial Edge Device Kit - arm64 V1.8, Industrial Edge Device Kit - arm64 V1.9, Industrial Edge Device Kit - x86-64 V1.10, Industrial Edge Device Kit - x86-64 V1.11, Industrial Edge Device Kit - x86-64 V1.12, Industrial Edge Device Kit - x86-64 V1.13, Industrial Edge Device Kit - x86-64 V1.14, Industrial Edge Device Kit - x86-64 V1.15, Industrial Edge Device Kit - x86-64 V1.16, Industrial Edge Device Kit - x86-64 V1.17, Industrial Edge Device Kit - x86-64 V1.18, Industrial Edge Device Kit - x86-64 V1.19, Industrial Edge Device Kit - x86-64 V1.20, Industrial Edge Device Kit - x86-64 V1.21, Industrial Edge Device Kit - x86-64 V1.22, Industrial Edge Device Kit - x86-64 V1.23, Industrial Edge Device Kit - x86-64 V1.24, Industrial Edge Device Kit - x86-64 V1.25, Industrial Edge Device Kit - x86-64 V1.26, Industrial Edge Device Kit - x86-64 V1.27, Industrial Edge Device Kit - x86-64 V1.28, Industrial Edge Device Kit - x86-64 V1.5, Industrial Edge Device Kit - x86-64 V1.6, Industrial Edge Device Kit - x86-64 V1.7, Industrial Edge Device Kit - x86-64 V1.8, Industrial Edge Device Kit - x86-64 V1.9, Industrial Edge Own Device (IEOD), Industrial Edge Virtual Device (IEVD), SCALANCE LPE9413 (6GK5998-3GS01-2AC2), SCALANCE LPE9433 (6GK5998-3GS11-2AC2), SIMATIC IoT2050 Advanced IED (6ES7647-0BW00-1YA2), SIMATIC IoT2050 SM IED (6ES7647-0CW00-1AA2), SIMATIC IPC BX-21A Industrial Edge Device, SIMATIC IPC BX-39A Industrial Edge Device, SIMATIC IPC BX-59A Industrial Edge Device, SIMATIC IPC127E Industrial Edge Device, SIMATIC IPC227E Industrial Edge Device, SIMATIC IPC227G Industrial Edge Device, SIMATIC IPC427E Industrial Edge Device, SIMATIC IPC847E Industrial Edge Device. Affected systems do not properly restrict access to internal APIs and paths for authenticated users. This could allow an authenticated remote attacker to access sensitive internal information, which in the worst case could be leveraged to facilitate unauthorized access to the system.
Что это значит
В источнике описана ошибка безопасности в перечисленных продуктах. Фактический риск зависит от установленной версии, конфигурации и доступности компонента; проверьте условия в первичном бюллетене.
Что делать
1. Проверьте, затронуты ли вы
Соберите инвентаризацию и сравните с таблицей затронутых версий. Эти команды только показывают установленные компоненты и сами по себе не доказывают наличие CVE.
dpkg-query -W -f='${Package} ${Version}\n'rpm -qa --qf '%{NAME}\t%{VERSION}-%{RELEASE}\n'Get-HotFix | Select-Object HotFixID, InstalledOn
2. Установите исправление
Сверьте точный продукт и версию с бюллетенем вендора. Установите указанное в нём исправление после резервного копирования и проверки совместимости. Подтверждённая целевая версия в источниках отсутствует.
3. Временные меры
До проверки бюллетеня ограничьте доступ к затронутому компоненту доверенными узлами. Оцените сегментацию и отключение ненужных интерфейсов с владельцем сервиса; универсального правила WAF для этой CVE не подтверждено.
4. Проверьте следы эксплуатации
Проверьте аномальные входы, новые учётные записи, ошибки и необычные дочерние процессы в затронутом сервисе. Публичные проверенные правила обнаружения не включены в запись; отсутствие сигналов не доказывает отсутствие компрометации.
5. После исправления
- Проверьте фактическую версию и результат установки по бюллетеню.
- При необходимости перезапустите сервисы в согласованное окно.
- Повторите проверку сканером и функциональные проверки.
- Зафиксируйте результат, дату, владельца и оставшийся риск.
Продукты и затронутые версии
Siemens / Industrial Edge Cloud Device (IECD)
{
"status": "affected",
"version": "0",
"lessThan": "V1.28.1",
"versionType": "custom"
}Siemens / Industrial Edge Device Kit - arm64 V1.10
{
"status": "affected",
"version": "0",
"lessThan": "*",
"versionType": "custom"
}Siemens / Industrial Edge Device Kit - arm64 V1.11
{
"status": "affected",
"version": "0",
"lessThan": "*",
"versionType": "custom"
}Siemens / Industrial Edge Device Kit - arm64 V1.12
{
"status": "affected",
"version": "0",
"lessThan": "*",
"versionType": "custom"
}Siemens / Industrial Edge Device Kit - arm64 V1.13
{
"status": "affected",
"version": "0",
"lessThan": "*",
"versionType": "custom"
}Siemens / Industrial Edge Device Kit - arm64 V1.14
{
"status": "affected",
"version": "0",
"lessThan": "*",
"versionType": "custom"
}Siemens / Industrial Edge Device Kit - arm64 V1.15
{
"status": "affected",
"version": "0",
"lessThan": "*",
"versionType": "custom"
}Siemens / Industrial Edge Device Kit - arm64 V1.16
{
"status": "affected",
"version": "0",
"lessThan": "*",
"versionType": "custom"
}Siemens / Industrial Edge Device Kit - arm64 V1.17
{
"status": "affected",
"version": "0",
"lessThan": "*",
"versionType": "custom"
}Siemens / Industrial Edge Device Kit - arm64 V1.18
{
"status": "affected",
"version": "0",
"lessThan": "*",
"versionType": "custom"
}Siemens / Industrial Edge Device Kit - arm64 V1.19
{
"status": "affected",
"version": "0",
"lessThan": "*",
"versionType": "custom"
}Siemens / Industrial Edge Device Kit - arm64 V1.20
{
"status": "affected",
"version": "0",
"lessThan": "*",
"versionType": "custom"
}Siemens / Industrial Edge Device Kit - arm64 V1.21
{
"status": "affected",
"version": "0",
"lessThan": "*",
"versionType": "custom"
}Siemens / Industrial Edge Device Kit - arm64 V1.22
{
"status": "affected",
"version": "0",
"lessThan": "*",
"versionType": "custom"
}Siemens / Industrial Edge Device Kit - arm64 V1.23
{
"status": "affected",
"version": "0",
"lessThan": "*",
"versionType": "custom"
}Siemens / Industrial Edge Device Kit - arm64 V1.24
{
"status": "affected",
"version": "0",
"lessThan": "*",
"versionType": "custom"
}Siemens / Industrial Edge Device Kit - arm64 V1.25
{
"status": "affected",
"version": "0",
"lessThan": "*",
"versionType": "custom"
}Siemens / Industrial Edge Device Kit - arm64 V1.26
{
"status": "affected",
"version": "0",
"lessThan": "V1.26.2-1",
"versionType": "custom"
}Siemens / Industrial Edge Device Kit - arm64 V1.27
{
"status": "affected",
"version": "0",
"lessThan": "V1.27.1-1",
"versionType": "custom"
}Siemens / Industrial Edge Device Kit - arm64 V1.28
{
"status": "affected",
"version": "0",
"lessThan": "V1.28.0-6",
"versionType": "custom"
}Siemens / Industrial Edge Device Kit - arm64 V1.5
{
"status": "affected",
"version": "0",
"lessThan": "*",
"versionType": "custom"
}Siemens / Industrial Edge Device Kit - arm64 V1.6
{
"status": "affected",
"version": "0",
"lessThan": "*",
"versionType": "custom"
}Siemens / Industrial Edge Device Kit - arm64 V1.7
{
"status": "affected",
"version": "0",
"lessThan": "*",
"versionType": "custom"
}Siemens / Industrial Edge Device Kit - arm64 V1.8
{
"status": "affected",
"version": "0",
"lessThan": "*",
"versionType": "custom"
}Siemens / Industrial Edge Device Kit - arm64 V1.9
{
"status": "affected",
"version": "0",
"lessThan": "*",
"versionType": "custom"
}Siemens / Industrial Edge Device Kit - x86-64 V1.10
{
"status": "affected",
"version": "0",
"lessThan": "*",
"versionType": "custom"
}Siemens / Industrial Edge Device Kit - x86-64 V1.11
{
"status": "affected",
"version": "0",
"lessThan": "*",
"versionType": "custom"
}Siemens / Industrial Edge Device Kit - x86-64 V1.12
{
"status": "affected",
"version": "0",
"lessThan": "*",
"versionType": "custom"
}Siemens / Industrial Edge Device Kit - x86-64 V1.13
{
"status": "affected",
"version": "0",
"lessThan": "*",
"versionType": "custom"
}Siemens / Industrial Edge Device Kit - x86-64 V1.14
{
"status": "affected",
"version": "0",
"lessThan": "*",
"versionType": "custom"
}Siemens / Industrial Edge Device Kit - x86-64 V1.15
{
"status": "affected",
"version": "0",
"lessThan": "*",
"versionType": "custom"
}Siemens / Industrial Edge Device Kit - x86-64 V1.16
{
"status": "affected",
"version": "0",
"lessThan": "*",
"versionType": "custom"
}Siemens / Industrial Edge Device Kit - x86-64 V1.17
{
"status": "affected",
"version": "0",
"lessThan": "*",
"versionType": "custom"
}Siemens / Industrial Edge Device Kit - x86-64 V1.18
{
"status": "affected",
"version": "0",
"lessThan": "*",
"versionType": "custom"
}Siemens / Industrial Edge Device Kit - x86-64 V1.19
{
"status": "affected",
"version": "0",
"lessThan": "*",
"versionType": "custom"
}Siemens / Industrial Edge Device Kit - x86-64 V1.20
{
"status": "affected",
"version": "0",
"lessThan": "*",
"versionType": "custom"
}Siemens / Industrial Edge Device Kit - x86-64 V1.21
{
"status": "affected",
"version": "0",
"lessThan": "*",
"versionType": "custom"
}Siemens / Industrial Edge Device Kit - x86-64 V1.22
{
"status": "affected",
"version": "0",
"lessThan": "*",
"versionType": "custom"
}Siemens / Industrial Edge Device Kit - x86-64 V1.23
{
"status": "affected",
"version": "0",
"lessThan": "*",
"versionType": "custom"
}Siemens / Industrial Edge Device Kit - x86-64 V1.24
{
"status": "affected",
"version": "0",
"lessThan": "*",
"versionType": "custom"
}Siemens / Industrial Edge Device Kit - x86-64 V1.25
{
"status": "affected",
"version": "0",
"lessThan": "*",
"versionType": "custom"
}Siemens / Industrial Edge Device Kit - x86-64 V1.26
{
"status": "affected",
"version": "0",
"lessThan": "V1.26.2-1",
"versionType": "custom"
}Siemens / Industrial Edge Device Kit - x86-64 V1.27
{
"status": "affected",
"version": "0",
"lessThan": "V1.27.1-1",
"versionType": "custom"
}Siemens / Industrial Edge Device Kit - x86-64 V1.28
{
"status": "affected",
"version": "0",
"lessThan": "V1.28.0-6",
"versionType": "custom"
}Siemens / Industrial Edge Device Kit - x86-64 V1.5
{
"status": "affected",
"version": "0",
"lessThan": "*",
"versionType": "custom"
}Siemens / Industrial Edge Device Kit - x86-64 V1.6
{
"status": "affected",
"version": "0",
"lessThan": "*",
"versionType": "custom"
}Siemens / Industrial Edge Device Kit - x86-64 V1.7
{
"status": "affected",
"version": "0",
"lessThan": "*",
"versionType": "custom"
}Siemens / Industrial Edge Device Kit - x86-64 V1.8
{
"status": "affected",
"version": "0",
"lessThan": "*",
"versionType": "custom"
}Siemens / Industrial Edge Device Kit - x86-64 V1.9
{
"status": "affected",
"version": "0",
"lessThan": "*",
"versionType": "custom"
}Siemens / Industrial Edge Own Device (IEOD)
{
"status": "affected",
"version": "0",
"lessThan": "V1.28.1",
"versionType": "custom"
}Siemens / Industrial Edge Virtual Device (IEVD)
{
"status": "affected",
"version": "0",
"lessThan": "V1.28.1",
"versionType": "custom"
}Siemens / SCALANCE LPE9413
{
"status": "affected",
"version": "0",
"lessThan": "*",
"versionType": "custom"
}Siemens / SCALANCE LPE9433
{
"status": "affected",
"version": "0",
"lessThan": "*",
"versionType": "custom"
}Siemens / SIMATIC IoT2050 Advanced IED
{
"status": "affected",
"version": "0",
"lessThan": "V1.28.1-2",
"versionType": "custom"
}Siemens / SIMATIC IoT2050 SM IED
{
"status": "affected",
"version": "0",
"lessThan": "V1.28.1-2",
"versionType": "custom"
}Siemens / SIMATIC IPC BX-21A Industrial Edge Device
{
"status": "affected",
"version": "0",
"lessThan": "V1.28.1-2",
"versionType": "custom"
}Siemens / SIMATIC IPC BX-39A Industrial Edge Device
{
"status": "affected",
"version": "0",
"lessThan": "V3.2.0-17",
"versionType": "custom"
}Siemens / SIMATIC IPC BX-59A Industrial Edge Device
{
"status": "affected",
"version": "0",
"lessThan": "V3.2.0-17",
"versionType": "custom"
}Siemens / SIMATIC IPC127E Industrial Edge Device
{
"status": "affected",
"version": "0",
"lessThan": "V3.2.0-17",
"versionType": "custom"
}Siemens / SIMATIC IPC227E Industrial Edge Device
{
"status": "affected",
"version": "0",
"lessThan": "V3.2.0-17",
"versionType": "custom"
}Siemens / SIMATIC IPC227G Industrial Edge Device
{
"status": "affected",
"version": "0",
"lessThan": "V3.2.0-17",
"versionType": "custom"
}Siemens / SIMATIC IPC427E Industrial Edge Device
{
"status": "affected",
"version": "0",
"lessThan": "V3.2.0-17",
"versionType": "custom"
}Siemens / SIMATIC IPC847E Industrial Edge Device
{
"status": "affected",
"version": "0",
"lessThan": "V3.2.0-17",
"versionType": "custom"
}CVSS: оценки и векторы
CVSS 3.1 · cve6.8
CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:C/C:H/I:N/A:N
CVSS 4.0 · cve6.9
CVSS:4.0/AV:N/AC:L/AT:P/PR:H/UI:N/VC:H/VI:N/VA:N/SC:H/SI:N/SA:N
Классы CWE
Источники и ссылки
Происхождение полей
{
"cwes": [
"cve"
],
"epss": {
"source": "epss",
"received_at": "2026-11-04T21:17:21.929701+00:00"
},
"scores": [
"cve"
],
"status": {
"source": "cve",
"received_at": "2026-10-28T19:29:21.916973+00:00"
},
"affected": [
"cve"
],
"published": {
"source": "cve",
"received_at": "2026-10-28T19:29:21.916973+00:00"
},
"solutions": [],
"percentile": {
"source": "epss",
"received_at": "2026-11-04T21:17:21.929701+00:00"
},
"references": [
"cve"
],
"description": {
"source": "cve",
"received_at": "2026-10-28T19:29:21.916973+00:00"
},
"workarounds": [],
"configurations": []
}Хронология записи
- Данные обновлены05.11.2026, 00:17
- Данные обновлены04.11.2026, 00:13
- Данные обновлены03.11.2026, 00:12
- Данные обновлены02.11.2026, 00:11
- Данные обновлены31.10.2026, 11:58
- Данные обновлены29.10.2026, 12:27
- Опубликована28.10.2026, 22:29
Личная заметка и статус
Другие CVE того же продукта
| УЯЗВИМОСТЬ / ПРОДУКТ | ПРИОРИТЕТ | CVSS | EPSS | СИГНАЛЫ | ОПУБЛИКОВАНА | Карточка |
|---|---|---|---|---|---|---|
| CVE-2025-40805 Affected devices do not properly enforce user authentication on specific API endpoints. This could f Siemens / Industrial Edge Cloud Device (IECD) · Siemens / Industrial Edge Device Kit - arm64 V1.10 | Критический | 10.0 | 0,65 % | 13.01.2026 |